Healthcare Technical Services Projects for March 05 |
- Created new Project in JCAPS 5.1.3 to
process Master File messages for providers to the ancillary systems
- Created new Connectivity Map for
processing Master Files and configured with needed components in JCAPS 5.1.3
- Created and configured new Deployment
Profile for processing Master Files in JCAPS 5.1.3
- Performed build and deploy on
Deployment Profile for processing Master Files in JCAPS 5.1.3
- Created new custom Object Type
Definition to be used as a template for a new OTD
- Created new Object Type Definition to
be used for messages destined to ancillary systems
- Created new Project in JCAPS 5.1.3 to
process Master File messages for providers to the ancillary Sunquest
system
- Created new Connectivity Map for
processing Master Files to Sunquest and configured with needed components in
JCAPS 5.1.3
- Created, validated, and compiled new
Java Collaboration Definition for processing Master Files to Sunquest in JCAPS
5.1.3
- Created and configured new Deployment
Profile for processing Master Files to Sunquest in JCAPS 5.1.3
- Performed build and deploy on
Deployment Profile for processing Master Files to Sunquest in JCAPS 5.1.3
- Started connectivity testing with the
ancillary system Clinical Work Station
- Performed modifications to resolve
issues with MRN and SSN format
- Started connectivity testing with the
ancillary system Dexter
- Started connectivity testing with the
ancillary system Midas
- Created new Project in JCAPS 5.1.3 to
process Epic ADT messages to the ancillary Relay Health system
- Created new Connectivity Map for
processing ADT to Relay Health and configured with needed components in JCAPS
5.1.3
- Created, validated, and compiled new
Java Collaboration Definition for processing ADT to Relay Health in JCAPS 5.1.3
- Created and configured new Deployment
Profile for processing ADT to Relay Health in JCAPS 5.1.3
- Performed build and deploy on
Deployment Profile for processing ADT to Relay Health in JCAPS 5.1.3
- Created new Project in JCAPS 5.1.3 to
process Epic ADT messages to the ancillary Pyxis system
- Created new Connectivity Map for processing ADT to Pyxis and configured
with needed components in JCAPS 5.1.3
- Created, validated, and compiled new Java Collaboration Definition for
processing ADT to Pyxis in JCAPS 5.1.3
- Created and configured new Deployment Profile for processing ADT to
Pyxis in JCAPS 5.1.3
- Performed build and deploy on Deployment Profile for processing ADT to
Pyxis in JCAPS 5.1.
- Completed build
of e*Gate components in production and completed cutover of the live ADT feed
from test to production.
- Identified
truncation bug with the “Copy To” field – HL7 OBR.28 – after the issue was
reported by Users. The provider mnemonic
was truncated to five characters when the mnemonic happened to be greater than
five bytes long. Tested the code change
and implemented the change in production.
Then completed the same code change for multiple remote site e*Gate
interfaces.
- Identified and
reported Meditech ITS inbound report rejections based on report type code
errors and provider mnemonic “PHYNS – Physician Non-Staff provider. Complete message re-sends after the necessary
Meditech dictionary entries were defined by client and all re-sent messages
filed successfully.
- Completed
integrated test of this interface working.
Three lead test results were tested with no issues.
- Completed e*Gate
changes and testing to implement filter rules for HL7 update (A08)
transactions. These changes filter out
A08 transactions for pre-admit patients and discharged patients.
- Completed e*Gate
configuration change to point to new Intego server at client site after pulling
together a conference call to discuss the timeline and impacts of the server
switch.
- Implemented
custom e*Way connection called “HL7TcpClient” that implements HL7 MLLP over
TCP/IP client in “TEST” for the client’s interface. Completed side by side test of “HL7TcpClient”
and the e*Gate standard “TCP/IP HL7 e*Way”.
Discovered that the “HL7TcpClient” reports “I/O Exception – connection
reset by peer” for the same conditions that cause the “TCP/IP HL7 e*Way” to
report the MLLP error “STX character not found”. In addition, Allscripts reported that they
only received one copy of the message for the “HL7TcpClient” test and two
copies for the “TCP/IP HL7 e*Way” test.
The conclusion drawn here is that it is worth piloting “HL7TcpClient”
for 3-4 days to see if it will resolve the duplicate report issue we are
currently experiencing. A final test if
planned for Monday afternoon with Allscripts.
- Completed initial
draft of the production implementation plan for this interface. Still need to complete the piece of the plan
that includes installing support for the MOVEIt software and associated MOVEit
FTPS script.
|
|