Healthcare Technical Services Projects for Feb 27 |
- Participated in tours of the radiology departments for the Client at their client facilities and clinics.
- Participated in planning and kickoff activities for the ePI and RIS implementation projects.
- Supported Activation ADT 3NSMED interface for Lawson Point of Use.
- Coded Lawson Point of Use Charge File transfer interface.
- Supported Activation of the Lawson Point of Use Charge File Transfer Interface.
- Developed tentative resolution on location issues in Lawson Point of Use.
- Assisted with ADT testing and issues resolution
- Monitor the BETA environment CENTRAL MPI and Escalate the findings to the concerned.
- Worked on Access manager URL (#) and provided workaround for client.
- Worked on adding users as requested by client, but could not complete because the users where seen when imported the specified ldap user group. Waiting on client to comeback on this.
- Checked if Nextgate HL7 Binding component Supports IP Address configuration and provided the feedback,
- Checked for C32 Errors on BETA environment
- Started Installing SQL Server as part of MPI local Installation But not able to succeed (still investigating the cause).
- Researched USA charges issue with new segment ZFT. Worked to isolate issue and identify which charges didn’t cross out of DataGate. Wrote script to isolate those charges and prep for resend through DataGate. Once tested and placed in production, resent charges from 2/17 through 2/20. Modified to only send charges that DataGate dropped.
- Modified structure (ssc), id/filter (isc) and translation code (tsc). Tested new code and presented for approval.
- Updated SOP with Broker information that one of the Broker interfaces was going to be down.
- Worked with Client to move DG1000 – CSS Qsight ADT interface into production.
- Documented DataGate Change Control for CS managers (and others) and distributed for QC.
- Validated USA charges from time of SRA and looked good. Manipulated charges from 2/21 to 2/22 (time of SRA) and prepped them for resend. Client validated the resend and then resent the charges.
- Researched Intellicred to Soft interface and Fax number issue.
- Attended the Soft DataGate Issues Meeting.
- Presented DataGate Change Control to the CS Manager’s meeting.
- Researched NOVO ORC:8 isssue for Client.
- Researched CareFusion test interface (turns out that CF had issues with their side of the interface but took me a while to track it down…)
- Soft to GE Flow Cytometry reports were fixed. No DataGate changes needed.
- Received ticket number R214289 for the QS fetal monitoring ADT interface for IFH. No action on this yet.
- Coded fix for Intellicred to Soft Fax numbers DG1005. Initially Tested. Will test with Monday afternoon’s data so validation can take place.
- Worked on IM 403702 – Soft Blood Bank record issue. Searched all over DataGate and could not find this BB record. Turns out it never left Soft and it is a work flow process issue.
- I removed the test interface from Intellicred to GECE so MSOW could be tested.
- Reviewed Soft Fax test data output.
- Worked on a down Powerscribe interface (PS_BU_O). Had to work with the vendor for them to find the right interface.
- Worked on the GECE to EKO interface in test to help find some records.
- Worked on researching an issue where Soft says they did not receive a cancel order originating from Picis. We were able to show that the record did go across. Early next week, I will run the script that creates a chronologically view of the log data for those interfaces.
- Client requested I look at a Powerscribe issue. Research found this issue to be with Powerscribe. Application support notified.
|
|