  • Continued ADT Unit testing and documenting results between Epic EMR and Witt ancillary system
  • Continued ADT Unit testing and documenting results between Epic EMR and Xim ancillary system
  • Continued ADT Unit testing and documenting results between Epic EMR and Integrated Health Record ancillary system
  • Continued ADT Unit testing and documenting results between Epic EMR and IntelliDesk ancillary system
  • Continued ADT Unit testing and documenting results between Epic EMR and Pyxis ancillary system
  • Performed maintenance and troubleshooting on eManager performance issues that administered designated testing domains.
  • Continued ADT Unit testing and documenting results between Epic EMR and Midas ancillary system
  • Modified Java Collaboration Definitions in JCAPS 5.1.3 to resolve issues discovered during Interface Unit Testing
  • Assisted client Integration Analyst with JCAPS 5.1.3 coding errors in Production environment
  • Attended technical kick of meeting for OnBase Enterprise Scanning product.
  • Participated in kick off call and began reviewing project related material and following up on initial questions from new client.
  • Analysis of Intersystems Ensemble Interface Engine.
  • Contacting system administrators of external system to provide connectivity
  • Re-establishing the connections
  • Looking for invalid records received from partner hospitals and making corrections and resending those records for processing.
  • Resolving eGate and JCAPS alerts and fixing the runtime errors.
  • Performing enhancements in existing JCAPS interfaces.
  • Data files transfers to partner clinics over the weekend.
  • Attending conference calls for Epic Change Control and other issues.
  • Interface design and development for CAMS project using JCAPS.
  • Developing new FTP interface in JCAPS.
  • Powerscribe – Completed the e*Gate build and unit testing for the ORU reports interface from Powerscribe to Meditech.  Created a new ETD to support the Powerscribe ORU message format.  Completed transformation business rules based on the approved Powerscribe Reports interface HL7 specification document and used sample ORU message pulled from the same document for unit testing. 
  • Transolutions – Continued the ADT backload to Transolutions (from e*Gate TEST server AEGT03) and completed delivery of all ADT messages up to Thursday 4/29.
  • Transolutions – Continued the ADT backload to Transolutions (from e*Gate TEST server AEGT029) and completed delivery of all ADT messages up to Thursday 4/29.
  • Optivox ADT – Completed integrated test of all ADT message types with direct participation from Optivox.
  • Optivox ADT – Completed integrated test of 50% of the ADT message types with direct participation from Optivox and will complete the final 50% of ADT message type testing early next week.  Generated all ADT transactions from the Meditech C/S test system for client using 3-4 test patients to cover the list of ADT events required for testing.
  • Allscripts – Received email reporting a recurrence of the duplicate report issue on Wednesday 4/28.  Using the screen prints provided, tracked down the offending HL7 messages in the e*Gate log files for the reports interface.  Discovered for each report that was duplicated in Allscripts, the associated HL7 report message was sent exactly once to the Allscripts server (also ACK’ed exactly once by Allscripts as well).  Subsequently sent email to interface support at Allscripts reporting the issue along with my findings with a request for them to research the issue on the Allscripts side.  As of Friday close of business, had not heard back from Allscripts.
  • Physician Integration (eMDS) – Completed changes and unit testing to the “HL7TcpClientETD” custom e*Way connection code in order to add support for the eMDS specific MLLP envelope that is currently being used for message ACK’s from the eMDS application back to e*Gate.  Added configurable parameter “EMDS Acknowledgment Envelope” and completed associated coding changes to support the new configurable parameter.  Subsequently, implemented the updated “HL7TcpClientETD” code in the production environment for the eMDS and Fox Valley components that utilize “HL7TcpClientETD”.