|
Jun 21
2010
|
Healthcare Technical Services Projects for June 20Posted by admin in Untagged |
|
- NPR Extract to MIDAS Abstracting – Participated in project kick-off meeting with the team to discuss the business needs and data requirements for this interface project. Subsequently completed detailed analysis of the batch record specifications on the NPR Extract side and the BAR^P01 specifications and sample messages from the MIDAS side.
- NPR Extract to MIDAS Abstracting – Completed development and unit testing of the “inbound batch file reader” component of the new e*Way for this interface. This new e*Way is a Multi-Mode e*Way that uses “LocalFileETD” and “BatchRecordETD” (Batch e*Way for Java ETD’s) to read and process data from input batch files. These files having been produced and delivered to a directory on the e*Gate server by the NPR Extract from Meditech.
- NPR Extract to MIDAS Abstracting – Completed development and unit testing of the “transformation” component of the new e*Way for this interface. This batch record to HL7 transformation builds a single HL7 v2.2 “BAR^P01” clinical abstract message from multiple input NPR Extract batch records. There are four NPR Extract record types containing Patient/Visit, Diagnosis, Procedure and Provider data. The Patient/Visit data items were mapped to PID and PV1, diagnosis data mapped to DG1, procedure data mapped to PR1 and ZDG and provider data mapped to ZDG.
- Transolutions – Completed change and integrated testing to default report status to “P” (pending) for all reports from Transolutions for the client. Tested one report after the change and confirm the change worked as designed. Subsequently implemented the change in production.
- Transolutions – Supported the implementation of the Meditech interface code change/fix in production for the two MAGIC ministries and the associated maximum line length change from 80 to 91 on the Transolutions side for ORU messages. Subsequently, supported additional Transolutions report testing for both client locations. Worked with client after a secondary change/fix was applied by Meditech support. The first change/fix caused issues with reports coming back from Epiphany where body text was missing from reports and this issue was reported.
- Heartland Cardiology Lab Results – Completed 50% of the development of the new e*Gate transformation BOB for the lab results interface from Meditech to MedInformatix. This new BOB will support the transformation required from the Meditech lab result ORU to the MedInformatix lab result ORU format as specified in the HL7 specification provided by the MedInformatix interface contact.
- Performed Unit Testing on 16 Epic ADT interfaces (uni/bi- directional).
- Performed Unit Testing on 4 Epic Lab interfaces (Orders/Results).
- Performed Unit Testing on 7 Epic Rad interfaces (Order/Results).
- Performed Unit Testing on 6 Epic Transcription interfaces.
- Performed Unit Testing on 2 Epic Charge interfaces.
- Performed Unit Testing on 1 Epic Master File Load.
- Coordinated the Interface component of Integrated testing of 14 scripts involving 19 different ancillary systems.
- Created new Project prjOutEpicAdtOnBase in JCAPS 5.1.3 to process Epic ADT messages to the OnBase system
- Created new Connectivity Map cmOutEpicAdtOnBase and configured with needed components in JCAPS 5.1.3
- Created, validated, and compiled new Java Collaboration Definition jcdOutEpicAdtOnBase in JCAPS 5.1.3
- Created new HL7 TCPIP External System esOutEpicAdtOnBase under designated domain in JCAPS 5.1.3
- Created and configured new Deployment Profile dpOutEpicAdtOnBase in JCAPS 5.1.3
- Performed build and deploy on Deployment Profile dpOutEpicAdtOnBase in JCAPS 5.1.3
- Created, built, and deployed Deployment profile for project prjInOnBaseTrns in JCAPS 5.1.3
- Created new Project prjOutOnBaseTrnsEpic in JCAPS 5.1.3 to process OnBase Transcription messages to the Epic system
- Created new Connectivity Map cmOutOnBaseTrnsEpic and configured with needed components in JCAPS 5.1.3
- Created, validated, and compiled new Java Collaboration Definition jcdOutOnBaseTrnsEpic in JCAPS 5.1.3
- Created new HL7 TCPIP External System esOutOnBaseTrnsEpic under designated domain in JCAPS 5.1.3
- Created and configured new Deployment Profile dpOutOnBaseTrnsEpic in JCAPS 5.1.3
- Performed build and deploy on Deployment Profile dpOutOnBaseTrnsEpic in JCAPS 5.1.3
- Performed Epic ADT Unit testing with OnBase vendor
- Performed MedQuist Transcription into Epic Unit testing with MedQuist vendor.
- Performed code modifications for 2 interfaces as per the specification documents as well as unit testing for these interfaces.
- Worked on eGate interface engine production clean up tasks including archiving unused *isc and *tsc files and configuration files.
- Restored production logs that had been overwritten and validated data reports.
- Wrote script to move logs after stopping and starting dgsrvr.
- Created documentation outlining production interfaces per client's specifications.
- Created documentation for interface analysis on current interface engine practices.
- Researched test environment "too many files open" error and created short term and long term option plan.
- Worked with client to create an interface request document.
- Completed analysis on Unix operating system error – “Too many files open” occurring with eGate TRE (DataGate). Created spreadsheet documenting all current interfaces and outlined interfaces and routes to move to another dgsrvr (table) instance.
- Created script to email previous day’s batch transfers report including system and files transferred to the eGate TRE (DataGate) system.
- Attended conference call on clients conversion from McKesson to Inova’s suite of systems.
- Worked on new user manual for Inova documenting eGate TRE (DataGate) operational procedures as well as Inova specific procedures.
- Heartland Cardiology Lab Results – Completed development of the new e*Gate transformation BOB for the lab results interface from Meditech to Medinformatix. This new BOB supports the transformation required from the Meditech lab result ORU to the Medinformatix lab result ORU format as specified in the HL7 specification provided by the Medinformatix interface contact.
- Heartland Cardiology Lab Results – Completed unit testing of the new transformation BOB. Subsequently pulled archive file of production lab result ORU messages for the client and pushed the messages through the new BOB creating an output file containing Medinformatix formatted lab result ORU messages. Set up script to de-identify all patient data in the messages, then sent the resulting test file (100 messages) to the Medinformatix interface contact for review. The VPN configuration/set up for this interface is still pending, so sent the file to keep things moving forward until the VPN configuration is complete.
- Powerscribe – Completed move/build of all e*Gate components for this interface to the e*Gate TEST environment (AEGT023/AEGT029). Subsequently exchanged Powerscribe/e*Gate IP Address and Port assignment information with the Powerscribe interface contact.
- Configured outbound HL7 e*Way to point to Powerscribe ADT/ORM listener and worked with Powerscribe contact to successfully test connectivity. Configured inbound HL7 e*Way to listen for Powerscribe ORU traffic and successfully tested connectivity. Also, completed research and confirmation of e*Gate / Meditech interface connectivity for the ADT outbound, ORM outbound and ORU inbound interfaces.
- Powerscribe – Completed test inpatient registration and entered test radiology order within the clients Meditech test system. Subsequently confirmed that the ORM order message was successfully transformed and routed to the Powerscribe test system. Received confirmation from Powerscribe interface contact that the ORM order message was successfully received and processed into Powerscribe. Currently waiting on the initial test of the ORU radiology report outbound from Powerscribe which will be completed by resources after/during training this week for the client staff.
- Cardiology Allscripts – Received a request to research an issue regarding “CATH” reports. Some of these reports were appearing with headings starting with “ISOVUE” and there was some question regarding whether these were “preliminary” reports. Completed research of the production reports in question for a particular patient. Subsequently identified a bug in the e*Gate with the handling of “CATH” report headings and fixed this bug by ensuring that all “CATH” reports are delivered with a consistent heading. Also, identified bug with e*Gate filter code for this interface that was not taking into account the “Dictated By” role and fixed this bug with a simple code change to include “Dictated By” in the filter logic. Tested the changes in TEST, then implemented the changes in production and notified client that the change was complete.
- Developed flow diagrams describing the interaction between Siemens and Misys registration and EAD.
- Performed and completed ADT and Transcription scan unit testing between Epic and vendor OnBase
- Made modification to JCD jcdOutEpicAdtOnBase in JCAPS 5.1.3 to accommodate for issues during testing
- Performed Blood Gas orders testing between Epic and vendor RapidLink
- Made modifications to JCD jcdOutEpicOrdRapidLink in JCAPS 5.1.3 to accommodate for issues found during testing
- Performed transcription message testing between Epic and vendor MedQuist
- Assisted in the troubleshooting and resolution of JCAPS server non-responsive issues
Bookmark
Email This
|
dress
April 15, 2011 122.194.54.45 Votes: +0 |
report abuse
vote down
vote up
|
|
conus Carl F. Bucherer replica
May 19, 2011 76.73.30.202 Votes: +0 |
Thanks for your sharing, this article is very good, I like it very much, as you learn a lot!-conus Carl F. Bucherer replica report abuse
vote down
vote up
|
Write comment


The services provided by Orchestrate Healthcare will
allow us to meet the interfacing and data migration deadlines required
on a very large and critical implementation project.